Model: EraFlash
HSX: Cannon Hoa Kì

ERAFLASH


ASTM D6450, ASTM D7094
ERAFLASH is preconfigured for the automatic measurement in full compliance with the latest and safest Continuously Closed Cup Flash Point (CCCFP) standards ASTM D6450 and ASTM D7084 and in excellent correlation with ASTM D93, ASTM D56, ASTM D3828 ISO 2719, ISO 13736, EN ISO 3679 and 3680. The innovative CCCFP methods use only 1 mL to 2 mL of sample that is sealed in a closed chamber during the whole measurement process. An electrical arc inside the chamber ignites the sample and the lack of oxygen extinguishes the flame automatically. The device measures the corresponding pressure increase inside the chamber.

Common Applications Include:
  • Fuel Oils
  • Diesel Fuel Oils
  • Gas Turbine Fuel Oils
  • Kerosene
  • Biodiesel Blend
  • Specifying Fuels
  • Analyzing Fresh and Used Lubricating Oils
  • Bitumen Testing
  • Flavors
  • Fragrances
  • Cosmetics
  • Paints
  • Varnishes
  • Hazardous Waste


ERAFLASH is preconfigured for the automatic measurement in full compliance with the latest and safest Continuously Close...

ERAFLASH is preconfigured for the automatic measurement in full compliance with the latest and safest Continuously Close...

Dimensions (W × D × H)29 cm × 35cm × 34cm (11.4in × 13.8in × 13.4 in)
Weight9.7 kg (21.4lb)
Available test methodsASTM D6450, ASTM D7094
Preprogrammed Correlation MethodsPensky Martens Closed Cup: ASTM D93, EN ISO 2719, DIN 51758, JIS K2265
TAG Closed Cup: ASTM D56
Abel Pensky Closed Cup: ISO 13736, IP 170
Small Scale Closed Cup and Flash/No Flash methods: ASTM D3828, EN ISO 3679, EN ISO 3680
Fuel Specifications (ASTM D7094)
ASTM D396, ASTM D975, ASTM D2880, ASTM D3699, ASTM D7467
Speed TestsFast screening test programs for unknown samples
Sample Volume1 mL (ASTM D6450) or 2 mL (ASTM D7094)
Sample ThroughputUp to 12 samples per hour
Temperature Range0 °C to 200 °C (32 °F to 390 °F) stand alone. No external chiller required.
Down to -25 °C (-13 °F) with water cooling/chiller
Up to 420 °C (788 °F) with optional High Temperature Module 
-40 °C to 120 °C (-40 °F to 248 °F) EREFLASH LT Model with external cooling
Temperature Stability0.1 °C (0.2 °F)
Fuel Dilution ProgramAutomatic fuel dilution measurement for used engine oils analysis
Result DatabaseOver 100,000 detailed test reports stored in internal memory
Power RequirementsAuto-switching 85 - 264 V AC, 47 - 63 Hz max. 150 W (multi-voltage power supply)
Field application: 12 V DC (vehicle battery) adaptor available