Thứ Năm, 30 tháng 5, 2019

Bể ổn nhiệt đo độ nhớt động học CT-600 Cannon

HSX: Cannon Hoa Kỳ
Model : CT-600

The CT-600 series constant temperature bath, with its external thermoelectric cooler, accommodates viscometer tubes requ...


CT-600 Series Constant Temperature Bath w/ Cooler

For Kinematic Viscosity  from 10 °C to 100 °C
ASTM D445/D446, ISO 3104/3105

Common Applications

  • Formulated oil analysis
  • Hydraulic oil analysis
  • Additive analysis
  • Marine fuel testing
  • Base stock analysis
  • Light and heavy fuel testing
  • Waxes/paraffin
  • Crude oil testing
  • Glycols
The CT-600 series constant temperature bath, with its external thermoelectric cooler, accommodates viscometer tubes requiring a bath depth up to 12" and provides reliable temperature control from 10 °C to 100 °C . The unit accommodates up to 7 simultaneous viscosity determinations.


Please call Mr Viet | P KD Hoa Ý | 0986817366

Máy đo tỷ trọng tự động loại cầm tay Cannon Densi-H

HSX: Cannon Hoa Kì

The handheld Densi-H is CANNON's most affordable instrument for measuring density and specific gravity. Lightweight and ...


Densi-H Handheld Density/Specific Gravity Meter

For On-site Measurement of Density, Specific Gravity and API Degrees
ASTM D7777

Common Applications

  • Petrochemicals (solvents, fuels, fuel oils. lubricants, crude oil)
  • Chemicals
  • Food and beverages
  • Battery acid tests
  • Electroplating and photo
  • Pharmaceuticals
  • Cosmetics
The handheld Densi-H is CANNON's most affordable instrument for measuring density and specific gravity. Lightweight and portable, Densi-H offers easy, one button operation and reports results in seconds. Densi-H operates on the oscillating tube principle.


Vui lòng liên hệ mr. Việt | P Kinh Doanh Hoa Ý | 0986817366

Dung dịch chuẩn chớp cháy | Flash Point Reference Materials

HSX: Cannon Hoa Kỳ

CANNON flash point reference materials are produced in accordance with ASTM D56, Tag Closed Cup Flash Point, ASTM D92, C...


Flash Point Reference Materials

ASTM D56, ASTM D92, ASTM D93
CANNON flash point reference materials are produced in accordance with ASTM D56, Tag Closed Cup Flash Point, ASTM D92, Cleveland Open Cup Flash Point and ASTM D93, Pensky Marten Closed Cup Flash Point. Lot specific data including average flash point and observed standard deviation from a statistical analyis of 40 tests in 20 different laboratories is provided with each standard. Flash Point Reference Materials are sold in 200 mL bottles.


Vui lòng liên Hệ: Mr. Việt | P. KD Hoa Ý | 0986817366

Nhớt kế pha loãng Ubblelohde Cannon

HSX: Cannon Hoa Kỳ

The Cannon-Ubbelohde Dilution Viscometer measures intrinsic viscosity of transparent Newtonian liquids according to ASTM...

CANNON-Ubbelohde Dilution Viscometers

Catalog NumberSizeApproximate Constant
(mm²/s²)
Viscosity Range (mm²/s)†
UncalibratedCalibratedLowHigh
9722-L509722-M50250.0020.52.0
9722-L539722-M53500.0040.84.0
9722-L569722-M56750.0081.68.0
9722-L599722-M591000.0153.015
9722-L629722-M621500.0357.035
9722-L659722-M652000.120100
9722-L689722-M683000.2550250
9722-L719722-M713500.5100500
9722-L749722-M744001.22401200
9722-L779722-M774502.55002500
9722-L809722-M805008.016008000
9722-L839722-M8360020400020000
† Viscosity ranges in mm²/s represent flow times of 250 to 1000 seconds for size 25
and 200 to 1000 seconds for all other sizes
The Cannon-Ubbelohde Dilution Viscometer measures intrinsic viscosity of transparent Newtonian liquids according to ASTM D445 and ISO 3104. Minimum sample volume is 8 mL (can be diluted to 40 mL). Minimum bath depth is 305 mm (12 in). The CANNON CT-518 bath is recommended. (CT-500 and CT-600 baths are not deep enough.) Viscometer constant is the same at all temperatures. Both calibrated and uncalibrated viscometers are available. Calibrated viscometers include a certificate of calibration and instruction sheet. Holders are sold separately.

Liên hệ Mr. Việt | P. Kinh Doanh Hoa Ý | 0986817366

Nhớt kế mao quản chảy ngược | CANNON-Fenske Opaque Viscometer (Reversed Flow)

HSX: Cannon Hoa Kỳ

The Cannon-Fenske Opaque Viscometer measures kinematic viscosity of transparent and opaque Newtonian liquids according t...


CANNON-Fenske Opaque Viscometers

Catalog NumberSizeApproximate Constant
(mm²/s²)
Viscosity Range (mm²/s)†
UncalibratedCalibratedLowHigh
9721-E509721-F50250.0020.42.0
9721-E539721-F53500.0040.84.0
9721-E569721-F56750.0081.68.0
9721-E599721-F591000.0153.015
9721-E629721-F621500.0357.035
9721-E659721-F652000.120100
9721-E689721-F683000.2550250
9721-E719721-F713500.5100500
9721-E749721-F744001.22401200
9721-E779721-F774502.55002500
9721-E809721-F805008.016008000
9721-E839721-F8360020400020000
9721-E869721-F8665045900045000
9721-E899721-F8970010020000100000
† Viscosity ranges in mm²/s represent flow times of 250 to 1000 seconds for size 25
and 200 to 1000 seconds for all other sizes
The Cannon-Fenske Opaque Viscometer measures kinematic viscosity of transparent and opaque Newtonian liquids according to ASTM D445, ISO 3104 and ASTM D2170. Minimum sample volume is 12 mL. Minimum bath depth is 230 mm (9 in). Special constant viscometers are available at additional cost. Both calibrated and uncalibrated viscometers are available. Calibrated viscometers include a certificate of calibration and instruction sheet. Holders are sold separately.

Please call Mr. Viet | 0986817366

CANNON-Fenske Routine Viscometer | Nhớt kế mao quản thủy tinh chảy xuôi Fenske

HSX: Cannon Hoa Kì

The Cannon-Fenske Routine Viscometer measures kinematic viscosity of transparent Newtonian liquids according to ASTM D44...

Catalog NumberSizeApproximate Constant
(mm²/s²)
Viscosity Range (mm²/s)†
UncalibratedCalibratedLowHigh
9721-A509721-B50250.0020.52.0
9721-A539721-B53500.0040.84.0
9721-A569721-B56750.0081.68.0
9721-A599721-B591000.0153.015
9721-A629721-B621500.0357.035
9721-A659721-B652000.120100
9721-A689721-B683000.2550250
9721-A719721-B713500.5100500
9721-A749721-B744001.22401200
9721-A779721-B774502.55002500
9721-A809721-B805008.016008000
9721-A839721-B8360020400020000
9721-A869721-B8665045900045000
9721-A899721-B8970010020000100000
† Viscosity ranges in mm²/s represent flow times of 250 to 1000 seconds for size 25
and 200 to 1000 seconds for all other sizes
The Cannon-Fenske Routine Viscometer measures kinematic viscosity of transparent Newtonian liquids according to ASTM D445 and ISO 3104. Minimum sample volume is 7 mL. Minimum bath depth is 203 mm (8 in). Both calibrated and uncalibrated viscometers are available. Calibrated viscometers include a certificate of calibration and instruction sheet. Holders are sold separately.


Please call Mr. Viet | 0986817366

Máy đo điểm chớp cháy tự động cho lượng mẫu ít Cannon USA

Model: EraFlash
HSX: Cannon Hoa Kì

ERAFLASH


ASTM D6450, ASTM D7094
ERAFLASH is preconfigured for the automatic measurement in full compliance with the latest and safest Continuously Closed Cup Flash Point (CCCFP) standards ASTM D6450 and ASTM D7084 and in excellent correlation with ASTM D93, ASTM D56, ASTM D3828 ISO 2719, ISO 13736, EN ISO 3679 and 3680. The innovative CCCFP methods use only 1 mL to 2 mL of sample that is sealed in a closed chamber during the whole measurement process. An electrical arc inside the chamber ignites the sample and the lack of oxygen extinguishes the flame automatically. The device measures the corresponding pressure increase inside the chamber.

Common Applications Include:
  • Fuel Oils
  • Diesel Fuel Oils
  • Gas Turbine Fuel Oils
  • Kerosene
  • Biodiesel Blend
  • Specifying Fuels
  • Analyzing Fresh and Used Lubricating Oils
  • Bitumen Testing
  • Flavors
  • Fragrances
  • Cosmetics
  • Paints
  • Varnishes
  • Hazardous Waste


ERAFLASH is preconfigured for the automatic measurement in full compliance with the latest and safest Continuously Close...

ERAFLASH is preconfigured for the automatic measurement in full compliance with the latest and safest Continuously Close...

Dimensions (W × D × H)29 cm × 35cm × 34cm (11.4in × 13.8in × 13.4 in)
Weight9.7 kg (21.4lb)
Available test methodsASTM D6450, ASTM D7094
Preprogrammed Correlation MethodsPensky Martens Closed Cup: ASTM D93, EN ISO 2719, DIN 51758, JIS K2265
TAG Closed Cup: ASTM D56
Abel Pensky Closed Cup: ISO 13736, IP 170
Small Scale Closed Cup and Flash/No Flash methods: ASTM D3828, EN ISO 3679, EN ISO 3680
Fuel Specifications (ASTM D7094)
ASTM D396, ASTM D975, ASTM D2880, ASTM D3699, ASTM D7467
Speed TestsFast screening test programs for unknown samples
Sample Volume1 mL (ASTM D6450) or 2 mL (ASTM D7094)
Sample ThroughputUp to 12 samples per hour
Temperature Range0 °C to 200 °C (32 °F to 390 °F) stand alone. No external chiller required.
Down to -25 °C (-13 °F) with water cooling/chiller
Up to 420 °C (788 °F) with optional High Temperature Module 
-40 °C to 120 °C (-40 °F to 248 °F) EREFLASH LT Model with external cooling
Temperature Stability0.1 °C (0.2 °F)
Fuel Dilution ProgramAutomatic fuel dilution measurement for used engine oils analysis
Result DatabaseOver 100,000 detailed test reports stored in internal memory
Power RequirementsAuto-switching 85 - 264 V AC, 47 - 63 Hz max. 150 W (multi-voltage power supply)
Field application: 12 V DC (vehicle battery) adaptor available